Mfg Part Number: R25-2-2.00A-B121EV | Alternate P/N: R252200AB121EV | Manufacturer: Sensata Technologies Inc |
NSN : 5925-01-322-7930 | NIIN : 013227930 | Item Name : circuit breaker |
CAGE Code : 81541 | FSC : 5925 Circuit Breakers |
Thank you for choosing NSN Part R25-2-2.00A-B121EV of Hardware and Fasteners for all your operational needs. You have reached our NSN RFQ page which features all of our highly sought-after NSN 5925-01-322-7930 parts and components with Circuit Breaker, manufactured by MFG Sensata Technologies Inc. Some of these items include part R25-2-2.00A-B121EV, and various others, all of which have been vetted for quality assurance and authenticity. At Hardware and Fasteners, we are committed to providing customers quality items that have been sourced from leading manufacturers across the globe. If you find yourself in need of quality parts and components, you have come to the right place.
R25-2-2.00A-B121EV part of NSN 5925-01-322-7930 products that we feature by MFG Sensata Technologies Inc are paired alongside CAGE Code 81541. Hardware and Fasteners uses CAGE Codes, allowing our customers to narrow down our vast catalogs with ease. When you find an item that works for your operations, fill out and submit an RFQ form for your comparisons. As you complete the form, please include target prices, desired quantities, and expected shipping time frames. Within 15 minutes of completion, an account manager will draft a sourcing solution that keeps your unique requirements in mind. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-322-7930 Item Description: Circuit Breaker | 5925 | 013227930 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
R25-2-2.00a-B121ev | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 1.550 INCHES MINIMUM AND 1.570 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.384 INCHES MINIMUM AND 1.404 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.810 INCHES MINIMUM AND 1.870 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS AND 65.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS AND 1000.0 DC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 15.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 3.0 AC AND 1.5 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 32.0 DC |
FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
AJEC | BOSS HEIGHT | 0.355 INCHES MINIMUM AND 0.385 INCHES MAXIMUM |
CPRX | ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
TTQY | TERMINAL TYPE AND QUANTITY | 4 QUICK DISCONNECT, MALE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 CLIP |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC ALL LOCATIONS AND 2.0 AMPERES DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
![]() |